The smart Trick of British Pendulum Skid Resistance Tester That Nobody is Discussing
The smart Trick of British Pendulum Skid Resistance Tester That Nobody is Discussing
Blog Article
ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6
When it comes to ensuring safety in business, commercial, and domestic areas, slip resistance testing is a critical element. At ATTAR (Advanced Technology Testing & Research), we concentrate on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to assist companies and homeowner alleviate risks and adhere to safety requirements.
With modern equipment such as the pendulum slip test machine and moisture meter for concrete, we offer precise and independent slip testing services throughout Australia. Our expertise covers ASTM F2170 compliance, R Rating assessments, P Score tiles, and more, ensuring your floorings satisfy the greatest security standards.
Why Slip Resistance Testing is Essential
Slips and falls are among the leading reasons for work environment and public injuries. Appropriate slip testing assists recognize harmful surface areas before mishaps occur. Whether you require damp pendulum test evaluations or pendulum test for slip resistance, ATTAR provides precise outcomes to boost security.
Secret Services Used by ATTAR
1. Floor Slip Resistance Testing
- Pendulum slip test (AS 4663).
- R Ranking and P Ranking tiles evaluations.
- Independent slip testing services for compliance.
2. Concrete Moisture Testing
- Slab moisture test utilizing sophisticated moisture meter for concrete.
- ASTM F2170 certified assessments.
- Concrete slab moisture testing to prevent flooring failures.
3. Luminance Contrast Testing
- Guarantees presence for visually impaired people.
- Complies with Australian ease of access standards.
4. On-Site & Laboratory Testing
- Slip test device for accurate on-site evaluations.
- Wet pendulum test for wet surface area slip resistance.
Comprehending Slip Resistance Rankings: R Score vs. P Score
When carrying out slip resistance testing, two key classifications are used:.
- R Rating (Ramp Test - DIN 51130)
Procedures slip resistance under lubricated conditions, frequently utilized in Europe.
- P Score (Pendulum Test - AS 4586)
Evaluates dynamic friction using a pendulum test slip resistance maker, extensively embraced in Australia.
ATTAR offers independent slip testing to identify whether your flooring satisfies the required pendulum score tiles requirements.
The Importance of Concrete Moisture Testing
Excess moisture in concrete slabs can lead to flooring failures, mold development, and adhesive degradation. Our concrete moisture testing services include:.
> ASTM F2170 compliant in-situ relative humidity testing.
> Moisture meter for concrete evaluations.
> Slab moisture test to make sure optimum conditions for floor setups.
By identifying moisture concerns early, we help prevent costly repairs and ensure lasting floor covering performance.
Luminance Contrast for Accessibility Compliance
Correct luminance contrast is vital for aesthetically impaired individuals to navigate areas securely. ATTAR evaluates:.
> Stair edges.
> Door frames.
> Handrails.
> Tactile indications.
Our evaluations guarantee compliance with Australian Impairment Standards (AS 1428.1).
Why Choose ATTAR for Slip Resistance & Moisture Testing?
> NATA Accredited (where applicable).
> Advanced Testing Devices (pendulum slip test, moisture meters).
> Nationwide Service Protection.
> Fast & Dependable Reporting.
For expert slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.
Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.
Common Applications of Slip Resistance Testing
1. Commercial & Retail Spaces
Shopping centres, dining establishments, and offices require safe floor covering to prevent customer and staff member injuries. Our pendulum slip test guarantees compliance with security policies.
2. Industrial & Storage Facility Facilities
High-traffic industrial environments require durable, slip-resistant floor covering. ATTAR's slip testing services help keep workplace security.
3. Healthcare & Aged Care Facilities
Health centers and assisted living home need to Pendulum Test Flooring reduce slip threats. Our luminance contrast and slip resistance testing guarantee safe movement for patients and personnel.
4. Public Facilities
Footpaths, train stations, and government structures require independent slip testing to fulfill accessibility and security standards.
How ATTAR Performs Slip Resistance Testing
Step 1: Surface Area Assessment
We assess floor covering materials and conditions (dry, damp, or infected).
Step 2: Pendulum Slip Test (AS 4663)
Using a slip test device, we determine the vibrant coefficient of friction (DCOF).
Step 3: Wet Pendulum Test
Mimics slippery conditions to examine real-world slip threats.
Step 4: Reporting & Compliance Certification
Comprehensive reports with R Score or P Ranking tiles classifications.
The Science Behind Pendulum Slip Testing
The pendulum test slip resistance method involves a swinging arm with a rubber slider that simulates a foot's motion. The test procedures:.
- Slip Potential Value (SPV).
- Pendulum score tiles category (P0 to P5).
Greater rankings (P4/P5) suggest much better slip resistance.
Moisture Testing for Concrete Floors: Avoiding Failures
Moisture-related flooring failures can be pricey. ATTAR's concrete slab moisture testing includes:.
- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete spot checks.
- Slab moisture test information analysis.
Conclusion
ATTAR (Advanced Technology Testing & Research) is Australia's trusted service provider of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast evaluations. With innovative technology like the pendulum slip test and moisture meter for concrete, we deliver accurate, independent, and certified testing services.
Guarantee your property meets safety requirements-- contact ATTAR today:.
44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.
By selecting ATTAR, you buy independent slip testing services, pendulum test slip resistance precision, and long-lasting floor security options. Let us assist you create safer, compliant, and moisture-resistant environments. Report this page